31 research outputs found

    Accuracy of color Doppler ultrasonography to identify malignancies in thyroid follicular neoplasms

    Get PDF
    Background. In most cases it is possible to differentiate between benign and malignant thyroid nodules through cytologic analysis of the fine-needle aspiration biopsy (FNAB) samples. However, in the case of follicular neoplasms (FNs), to determine whether such nodules are benign or malignant, it is necessary to perform a surgical biopsy, which requires the removal of at least part of the thyroid gland. There are clues in the literature that the parameters of color Doppler ultrasonography (CDU) may indicate a greater or lesser likelihood of malignancy in these nodules. Objective. The purpose of this systematic review was to obtain summary estimates of the diagnostic accuracy of CDU in predicting malignancy in thyroid FNs. Methods. We searched Medical Subject Headings together with the search terms “follicular,” “thyroid,” and “Doppler” in the MEDLINE, Web of Science, Cochrane Library and Excerpta Medica databases as well as the Latin American and Caribbean Health Sciences Literature database, after which we performed manual searches of the reference lists to locate additional studies. There were no language restrictions. We included studies that assessed the diagnostic accuracy of CDU in identifying malignancy in thyroid FNs. The assessments of the quality and extraction of data were performed by 2 independent reviewers. Results. We included 4 studies, which collectively evaluated 457 thyroid FNs, 67 of which had been classified as malignant based on the evaluation of surgical biopsy samples. Moderate, rich, predominant, or exclusive internal flow on CDU of thyroid FNs was considered indicative of malignancy. The overall sensitivity of CDU was 85% (95% confidence interval [CI], 74%–93%), with an overall specificity of 86% (95% CI, 82%–89%). The overall prevalence was 14.7%, and the positive and negative predictive values were 51% and 97%, respectively. The positive likelihood ratio was 6.07, and the negative likelihood ratio was 0.18. Conclusion. CDU has good accuracy for identifying malignancy in thyroid FN. Predominant internal flow seen on CDU is associated with malignancy of thyroid FN.Contexto. A diferenciação entre os nódulos benignos e malignos da tireoide é possível na maioria das vezes pela citologia, obtida por punção aspirativa com agulha fina (PAAF). No caso das neoplasias foliculares (NFs), é necessária a remoção cirúrgica de ao menos parte da glândula, pois somente a análise histológica da peça permite diferenciar nódulos benignos de malignos. Há indícios na literatura de que os parâmetros de ultrassonografia com Doppler colorido (UDC) podem indicar maior ou menor probabilidade de malignidade nesses nódulos. Objetivo. Avaliar, nesta revisão sistemática, a acurácia diagnóstica da UDC em predizer malignidade em NFs da tireoide. Métodos. Foram pesquisadas as seguintes bases de dados: MEDLINE, Web of Science, EMBASE, Cochrane Library e LILACS. As referências de estudos relevantes foram verificadas para adicionais citações de interesse. Não houve restrições de linguagem. Foram incluídos estudos nos quais nódulos de tireoide com padrão histológico compatível com NFs, confirmado por biópsia de peça cirúrgica, haviam sido previamente submetidos à UDC e cujos padrões de fluxo ao mapeamento colorido foram descritos detalhadamente. Dois revisores realizaram independentemente a avaliação da qualidade e a extração de dados. Resultados. Foram incluídos quatro estudos, somando 457 nódulos, sendo que 67 foram considerados malignos com base na biópsia cirúrgica. A presença à UDC de padrões de fluxo no interior do nódulo considerado como moderado, rico, predominante ou exclusivo foi indicativa de malignidade com uma sensibilidade média de 85 % (Intervalo de confiança [IC] 95%: 74% a 93%) e especificidade média de 86% (IC 95%: 82% a 89%). Para uma prevalência média de 14,7%, os valores preditivos positivo e negativo são respectivamente 51% e 97%. A razão de verossimilhança positiva é 6,07, e a razão de verossimilhança negativa 0,18. Conclusão. A UDC apresenta boa acurácia para identificar malignidade em NFs da tireóide. Fluxo interno predominante à UDC está associado a maior risco de malignidade nessas lesões.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)TEDEBV UNIFESP: Teses e dissertaçõe

    Acurácia diagnóstica da ultrassonografia nos derrames pleurais: revisão sistemática

    Get PDF
    CONTEXT AND OBJECTIVE: The initial method for evaluating the presence of pleural effusion was chest radiography. Isolated studies have shown that sonography has greater accuracy than radiography for this diagnosis; however, no systematic reviews on this matter are available in the literature. Thus, the aim of this study was to evaluate the accuracy of sonography in detecting pleural effusion, by means of a systematic review of the literature. DESIGN AND SETTING: This was a systematic review with meta-analysis on accuracy studies. This study was conducted in the Department of Diagnostic Imaging and in the Brazilian Cochrane Center, Discipline of Emergency Medicine and Evidence-Based Medicine, Department of Medicine, Universidade Federal de São Paulo (UNIFESP), São Paulo, Brazil. METHOD: The following databases were searched: Cochrane Library, Medline, Web of Science, Embase and Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs). The references of relevant studies were also screened for additional citations of interest. Studies in which the accuracy of sonography for detecting pleural effusion was tested, with an acceptable reference standard (computed tomography or thoracic drainage), were included. RESULTS: Four studies were included. All of them showed that sonography had high sensitivity, specificity and accuracy for detecting pleural effusions. The mean sensitivity was 93% (95% confidence interval, CI: 89% to 96%), and specificity was 96% (95% CI: 95% to 98%). CONCLUSIONS: In different populations and clinical settings, sonography showed consistently high sensitivity, specificity and accuracy for detecting fluid in the pleural space.CONTEXTO E OBJETIVOS: O método inicial para a avaliação da presença dos derrames pleurais foi a radiografia de tórax. Estudos isolados demonstraram que a ultrassonografia apresenta uma acurácia maior que a radiografia para este diagnóstico, entretanto, não se encontram disponíveis na literatura revisões sistemáticas sobre este tema. Assim, o objetivo deste estudo é avaliar a acurácia da ultrassonografia na detecção de derrame pleural, por meio de revisão sistemática da literatura. TIPO DE ESTUDO E LOCAL: Revisão sistemática com metanálise de estudos de acurácia. O estudo foi conduzido no Departamento de Diagnóstico por Imagem e no Centro Cochrane do Brasil/Disciplina de Medicina de Urgência e Medicina Baseada em Evidências do Departamento de Medicina, Universidade Federal de São Paulo (UNIFESP), São Paulo, Brazil. MÉTODOS: Foram pesquisadas as seguintes bases de dados: Cochrane Library, Medline, Web of Science, Embase e Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs). As referências de estudos relevantes foram verificadas para adicionais citações de interesse. Foram incluídos estudos nos quais a acurácia da ultrassonografia para a detecção de derrame pleural tenha sido testada, com padrão referência aceitável (tomografia computadorizada ou drenagem torácica). RESULTADOS: Foram incluídos quatro estudos. Todos apresentaram alta sensibilidade, especificidade e acurácia para a detecção de derrame pleural pela ultrassonografia. A sensibilidade média foi de 93% (intervalo de confiança, IC 95%: 89% a 96%), e a especificidade 96% (IC 95%: 95% a 98%). CONCLUSÕES: A ultrassonografia, em diferentes populações e cenários clínicos, apresentou consistentemente alta sensibilidade, especificidade e acurácia na detecção de líquido no espaço pleural.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Department of Diagnostic ImagingUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Brazilian Cochrane CenterUNIFESP, EPM, Department of Diagnostic ImagingUNIFESP, EPM, Brazilian Cochrane CenterSciEL

    Avaliação comparativa entre a mamografia digital e mamografia em filme: revisão sistemática e metanálise

    Get PDF
    CONTEXT AND OBJECTIVE: Mammography is the best method for breast-cancer screening and is capable of reducing mortality rates. Studies that have assessed the clinical impact of mammography have been carried out using film mammography. Digital mammography has been proposed as a substitute for film mammography given the benefits inherent to digital technology. The aim of this study was to compare the performance of digital and film mammography. DESIGN: Systematic review and meta-analysis. METHOD: The Medline, Scopus, Embase and Lilacs databases were searched looking for paired studies, cohorts and randomized controlled trials published up to 2009 that compared the performance of digital and film mammography, with regard to cancer detection, recall rates and tumor characteristics. The reference lists of included studies were checked for any relevant citations. RESULTS: A total of 11 studies involving 190,322 digital and 638,348 film mammography images were included. The cancer detection rates were significantly higher for digital mammography than for film mammography (risk relative, RR = 1.17; 95% confidence interval, CI = 1.06-1.29; I² = 19%). The advantage of digital mammography seemed greatest among patients between 50 and 60 years of age. There were no significant differences between the two methods regarding patient recall rates or the characteristics of the tumors detected. CONCLUSION: The cancer detection rates using digital mammography are slightly higher than the rates using film mammography. There are no significant differences in recall rates between film and digital mammography. The characteristics of the tumors are similar in patients undergoing the two methods.CONTEXTO E OBJETIVO: A mamografia é o melhor método para rastreamento do câncer de mama, capaz de reduzir a mortalidade. Os estudos que avaliam seu impacto clínico foram realizados com mamografia em filme. A mamografia digital é proposta para substituir a mamografia em filme com benefícios inerentes à tecnologia digital. O objetivo do estudo foi comparar o desempenho da mamografia digital com a mamografia em filme. TIPO DE ESTUDO: Revisão sistemática e metanálise. MÉTODO: Foram pesquisadas as bases Medline, Scopus, Embase e Lilacs, buscando-se por estudos pareados, coortes e ensaios clínicos randomizados comparando a mamografia digital e a mamografia em filme, quanto à taxa de detecção de câncer, de reconvocação e características dos tumores, publicados até 2009. As referências dos estudos incluídos foram verificadas em busca de citações relevantes. RESULTADOS: Foi incluído um total de 11 estudos, somando 190.322 mamografias digitais e 638.348 em filme. A taxa de detecção do câncer pela mamografia digital foi significantemente maior (risco relativo, RR: 1,17 [95% intervalo de confiança, IC = 1,06-1,29 I² = 19%]) do que pela mamografia em filme. A vantagem da mamografia digital parece maior em pacientes entre 50 e 60 anos. Não houve diferenças significantes nas taxas de reconvocação de pacientes e nas características dos tumores encontrados. CONCLUSÃO: A mamografia digital apresenta taxa de detecção de câncer pouco maior que a mamografia em filme. Não há diferenças significantes nas taxas de reconvocação entre a mamografia digital e a em filme. As características dos tumores são semelhantes em pacientes em ambos os métodos.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Universidade Federal de São Paulo (UNIFESP) Department of Diagnostic ImagingUniversidade Federal de São Paulo (UNIFESP)Universidade Federal de São Paulo (UNIFESP) Department of MedicineUNIFESP, Department of Diagnostic ImagingUNIFESP, Department of MedicineSciEL

    O valor da espessura cortical renal em predizer a função renal em pacientes renais crônicos

    Get PDF
    Objetivo: determinar se existe relação linear entre a espessura do córtex renal, comprimento bipolar e a espessura do parênquima renal em pacientes com insuficiência renal crônica que apresentam diferentes taxas de filtração glomerular (TFGs) e avaliar a reprodutibilidade dessas medidas. Materiais e métodos: exames ultrassonográficos foram realizados em 54 pacientes com insuficiência renal crônica, por dois radiologistas, de modo independente e duplo-cego. A estimativa da TFG foi calculada pela equação de Cockcroft-Gault. A concordância interobservador e o coeficiente de correlação linear (r) foram calculados para estabelecer se existe relação entre medidas renais e a TFG. Resultados: a espessura do córtex renal apresentou moderada correlação com a TFG (r = 0,478; p < 0,001). O comprimento bipolar e a espessura do parênquima apresentaram fraca correlação, com valores de r = 0,380 (p = 0,004) e r = 0,277 (p = 0,116), respectivamente. A concordância interobservador foi excelente para a espessura cortical (0,754) e comprimento bipolar (0,833) e satisfatória para a espessura do parênquima (0,523). Conclusão: a reprodutibilidade das medidas obtidas entre os radiologistas foi boa. A relação entre a TFG estimada com a espessura do córtex renal apresentou moderada correlação e o comprimento bipolar e a espessura do parênquima renal apresentaram fraca correlação.Objective: to determine the presence of linear relationship between renal cortical thickness, bipolar length, and parenchymal thickness in chronic kidney disease patients presenting with different estimated glomerular filtration rates (GFRs) and to assess the reproducibility of these measurements using ultrasonography. Materials and methods: ultrasonography was performed in 54 chronic renal failure patients. The scans were performed by two independent and blinded radiologists. The estimated GFR was calculated using the Cockcroft-Gault equation. Interobserver agreement was calculated and a linear correlation coefficient (r) was determined in order to establish the relationship between the different renal measurements and estimated GFR. Results: the correlation between GFR and measurements of renal cortical thickness, bipolar length, and parenchymal thickness was, respectively, moderate (r = 0.478; p < 0.001), poor (r = 0.380; p = 0.004), and poor (r = 0.277; p = 0.116). The interobserver agreement was considered excellent (0.754) for measurements of cortical thickness and bipolar length (0.833), and satisfactory for parenchymal thickness (0.523). Conclusion: the interobserver reproducibility for renal measurements obtained was good. A moderate correlation was observed between estimated GFR and cortical thickness, but bipolar length and parenchymal thickness were poorly correlated

    Accuracy of color Doppler ultrasonography to identify malignancies in thyroid follicular neoplasms

    Get PDF
    Background. In most cases it is possible to differentiate between benign and malignant thyroid nodules through cytologic analysis of the fine-needle aspiration biopsy (FNAB) samples. However, in the case of follicular neoplasms (FNs), to determine whether such nodules are benign or malignant, it is necessary to perform a surgical biopsy, which requires the removal of at least part of the thyroid gland. There are clues in the literature that the parameters of color Doppler ultrasonography (CDU) may indicate a greater or lesser likelihood of malignancy in these nodules. Objective. The purpose of this systematic review was to obtain summary estimates of the diagnostic accuracy of CDU in predicting malignancy in thyroid FNs. Methods. We searched Medical Subject Headings together with the search terms “follicular,” “thyroid,” and “Doppler” in the MEDLINE, Web of Science, Cochrane Library and Excerpta Medica databases as well as the Latin American and Caribbean Health Sciences Literature database, after which we performed manual searches of the reference lists to locate additional studies. There were no language restrictions. We included studies that assessed the diagnostic accuracy of CDU in identifying malignancy in thyroid FNs. The assessments of the quality and extraction of data were performed by 2 independent reviewers. Results. We included 4 studies, which collectively evaluated 457 thyroid FNs, 67 of which had been classified as malignant based on the evaluation of surgical biopsy samples. Moderate, rich, predominant, or exclusive internal flow on CDU of thyroid FNs was considered indicative of malignancy. The overall sensitivity of CDU was 85% (95% confidence interval [CI], 74%–93%), with an overall specificity of 86% (95% CI, 82%–89%). The overall prevalence was 14.7%, and the positive and negative predictive values were 51% and 97%, respectively. The positive likelihood ratio was 6.07, and the negative likelihood ratio was 0.18. Conclusion. CDU has good accuracy for identifying malignancy in thyroid FN. Predominant internal flow seen on CDU is associated with malignancy of thyroid FN.Contexto. A diferenciação entre os nódulos benignos e malignos da tireoide é possível na maioria das vezes pela citologia, obtida por punção aspirativa com agulha fina (PAAF). No caso das neoplasias foliculares (NFs), é necessária a remoção cirúrgica de ao menos parte da glândula, pois somente a análise histológica da peça permite diferenciar nódulos benignos de malignos. Há indícios na literatura de que os parâmetros de ultrassonografia com Doppler colorido (UDC) podem indicar maior ou menor probabilidade de malignidade nesses nódulos. Objetivo. Avaliar, nesta revisão sistemática, a acurácia diagnóstica da UDC em predizer malignidade em NFs da tireoide. Métodos. Foram pesquisadas as seguintes bases de dados: MEDLINE, Web of Science, EMBASE, Cochrane Library e LILACS. As referências de estudos relevantes foram verificadas para adicionais citações de interesse. Não houve restrições de linguagem. Foram incluídos estudos nos quais nódulos de tireoide com padrão histológico compatível com NFs, confirmado por biópsia de peça cirúrgica, haviam sido previamente submetidos à UDC e cujos padrões de fluxo ao mapeamento colorido foram descritos detalhadamente. Dois revisores realizaram independentemente a avaliação da qualidade e a extração de dados. Resultados. Foram incluídos quatro estudos, somando 457 nódulos, sendo que 67 foram considerados malignos com base na biópsia cirúrgica. A presença à UDC de padrões de fluxo no interior do nódulo considerado como moderado, rico, predominante ou exclusivo foi indicativa de malignidade com uma sensibilidade média de 85 % (Intervalo de confiança [IC] 95%: 74% a 93%) e especificidade média de 86% (IC 95%: 82% a 89%). Para uma prevalência média de 14,7%, os valores preditivos positivo e negativo são respectivamente 51% e 97%. A razão de verossimilhança positiva é 6,07, e a razão de verossimilhança negativa 0,18. Conclusão. A UDC apresenta boa acurácia para identificar malignidade em NFs da tireóide. Fluxo interno predominante à UDC está associado a maior risco de malignidade nessas lesões
    corecore